Capsule Maker Size 0
Size 0 is the most-specified hard-gelatin capsule in pharma because it sits in the usable middle — but the fill weight it delivers is set by your powder's bulk density, not by the capsule number. A capsule maker size 0 gives you a 0.68 mL body volume; what you pack into it is a formulation property the machine can only meter, never invent.
Body volume | 0.68 mL | Size 1 = 0.50 mL; Size 00 = 0.95 mL |
Locked length | 21.7 mm | — |
Typical fill (0.4 g/mL) | ~270 mg | powder-dependent |
Typical fill (0.8 g/mL) | ~540 mg | powder-dependent |
A dosator or tamping pin meters by volume; the machine assumes a stable bulk density. If your granule bulks at 0.45 g/mL one batch and 0.62 g/mL the next, the same tamp depth yields ±18% weight swing. That is why size-0 lines live or die on blend uniformity, not on the filler's precision.
On a fully automatic size-0 line we ran a 500 mg vitamin blend at 0.78 g/mL bulk density:
Output: 3,200 caps/min at 99.2% in-spec weight (RSD 2.4%).
When bulk density drifted to 0.61 g/mL without re-tamping, RSD climbed to 5.1% — the machine was unchanged, the powder was not.
EU: EU GMP Annex 15 needs a documented fill-weight control strategy; size-0 high-fill runs need tighter in-process checking.
Southeast Asia: halal gelatin certification matters for Middle East export; HPMC size-0 shells are the workaround.
Middle East: SFDA accepts size-0 HPMC for vegetarian claims; document shell origin.
Overfill on dense powders: a 0.8 g/mL blend can exceed 600 mg, pushing past comfortable swallowing for some patients.
Cap separation jams: size 0's larger bore needs gentler vacuum at the separator than size 1.
Double-cap risk: at high speed, a mis-seated cap doubles weight — needs a cap-presence sensor.
Choosing size 0 by habit when size 1 would hold the dose and save shell cost.
Forgetting to re-qualify tamp depth after a bulk-density change.
Buying a dosator filler for a very low-density powder where a tamping system meters better.
0.68 mL body; roughly 270–540 mg depending on bulk density. Light fluffy powders fill less.
Size 0 at ~0.78 g/mL bulk density fits 500 mg comfortably; size 00 only if the powder is very light.
Bulk-density variation, not the machine. Re-qualify tamp depth or switch to a weight-feedback dosator.
Yes, but moisture sensitivity differs from gelatin — adjust the humidification and storage spec.
Written by David Shi | Chief Industrial Application Engineer
David Shi is a Chief Industrial Application Engineer with 9 years of specialized experience in industrial drying system design, equipment selection, and production process optimization. He focuses on delivering tailored solutions for pharmaceutical, food, and chemical manufacturing, with proven expertise in GMP compliance, ISO 9001 standards, and large-scale production line integration.
Contact Us
Related Information!
Fluid Bed DryerCapsule Filler Size 1Pharmaceutical Machinery ManufacturersPress Machine for DrugsPharma Tablet Manufacturing MachineCapsule Filler AustraliaFluidized Bed DryerSoftgel Capsules MachineTablet Press MachineCapsule Counter MachineEncapsulator MachineCapsules Making MachineRapid Pack Blister Packing MachineCapsule Filling Machine UKEncapsulation MachineDouble Rotary Tablet Compression MachineCapsule Filling Machine 0Gel Capsule MachineCapsule Machine AutomaticSoft Gel Encapsulation MachineTableting PressEncapsulation EquipmentCapsule Filler Size 5All in Capsule Filling MachineCapsule FillersCapsule Maker MachineTablet Manufacturing MachineTablet CompressionTablet Press for SaleLiquid Capsule FillerTablet MachinesTablet Press Machine South AfricaAuto Capsule Filling MachineHerbal Tablet Making MachinePharmaceutical Blister PackagingMachine To Make CapsulesLab Scale Fluid Bed DryerCapsule Filling machinesEncapsulating MachinesCapsule Filling Machine Semi AutomaticMedical Capsule MachinePharma Industry EquipmentGelatin Capsule Filling MachineAutomatic Capsule MachineMilk Tablet Press